Brass Parts
Exporter of Brass Fitting Components Worldwide
Select Language

Cable Glands

 

Alco Cable Gland
Size
:
G 204 TO G 755
Brass Alco Cable gland
Application
:
Used with SWA, plastic and rubber sheathed cables.
Used indoor conditions inner ring frames positive armour clamp an earth continuity.
Material is brass and nickel plated.
     
Marine Cable Gland
Size
:
10 mm to 70 mm
Brass Marine Cable Gland
Application
:
Used for various marine applications.
     
     
     
TRS Cable Gland
Size
:
16 mm to 32 mm
Brass TRS Cable gland
Application
:
While not manufactured to a specific standard, are accepted by many contractors and uses as satisfactory method of securing flexible cables.
     

 

Wiping Gland
Size
:
As per drawings and specifications.
wping cable gland
 
     
     
     
 
Our brass parts range in cable glands include PG cable gland, BW 2 part cable gland, BW 3 part cable gland, CW cable gland, E1W cable gland, A2 type cable gland, TRS type cable gland and alco type cable gland.

Currently available cable glands accessories : Cable Glands Accessories
Lock Nuts
Earthing Tags
Cable Gland Kit Packaging
PVC Shrouds

Brass A2 Type Cable Glands

To BS 6121 pt. 1 suitable for unarmoured or rubber sheathed cables
Used for indoor as well as outdoor applications
Gland size: From 16 mm to 75 mm.

Brass PG Cable Glands

To DIN - 46320/46255 .
Available with strain relief facility with round or hex intermediate sockets.
Available in long and short antithreads.
Gland size: PG 9 to PG 56

Brass BW 2 Part Cable Glands

To BS 6121 pt.
Most suitable for SWA, plastic of rubber (Elastomer) sheathed cables.
Used in dry indoor conditions.
No loose parts and easy to install.
Save times & money.
Can be supplied with integral earth facility.
Gland size: 20 mm to 75 mm (S & L)


Brass E1W Cable Glands

To BS 6121 pt. 1 suitable for SWA or rubber sheathed cables.
Outer seal grips bedding layer of cable for use in most climatic conditions.
Weather proof and water proof.
Design has seperate armour lock rings.
Can be supplied with integral earth facility.
Gland size: 20 mm to 75 mm (S & L)

Brass BW 3 Part Cable Glands

To BS 6212 pt. 1 most suitable for SWA plastic or rubber sheathed cables.
Used indoor conditions.
Seperate locking ring helps to clamp the armour properly.
Can be supplied with integral earth facility.
Gland size: 20 mm to 75 mm (S & L)

Brass TRS Type Cable Glands

While not manufactured to a specific standard, are accepted by many contractors and users as satisfactory method of securing flexible cables.
Gland size: 16 mm to 32 mm

Brass CW Cable Glands

To BS 6212 pt. 1 most suitable for SWA plastic or rubber sheathed cables.
Outer seal grips sheath of cable for use in most climatic conditions.
Weather proof and water proof design.
Has seperate armour lock rings, can be supplied with integral earth facility.
Gland size: 20 mm to 75 mm (S & L)

Cable Gland Kit Packing

Gland Kit is a ready to use pack
It contains Glands, Lock Nuts, Earth Tags and PVC Shrouds.
Contains two sets upto 32 mm and one set for bigger size
It is a convenient way for the user to purchase complete cable termination as he is assured of all the required parts.
Free header card with customer home and logo can be provided. etc

 

CABLE GLAND SECTION CHART
FOR BS 6346 TYPE SWA CABLES

600/1000 V copper Conductor PVC Insulated with Steel Wire Armour Cable
Cable Conductor Size Number of Cores
Area mm2 Neutral 1 2 3 4 5 7 10 12 19 27 37 48
1.5     20s 20s   20s 20s 20s 20 20 25 25 32 32
2.5     20s 20s   20s 20s 20 25 25 25 32 32 40
4     20s 20s   20 20 25 25 25 32 40 40 50
6     20s 20   20                
10     25 25   25                
16     25 25   25                
25 16   25 25 32 32                
35 16   25 32 32 32                
50 25 25 32 32 32 40                
70 35 25 32 40 40 40                
95 50 25 40 40 50 50                
120 70 25 40 50 50 50                
150 70 32 40 50 50 50                
185 95 32 50 50 63 63                
240 120 40 50 63 63 63                
300 150 40 63 63 75 75                
300 185       75                  
400 185 50 63 75 75 75                
500   50                        
630   50                        
800   63                        
1000   63                        

Glands manufactured as per BS 6121 PT 1 : 1989 for use with PVC SWA PVC 600/1000 V cables to BS 6346 : 1989

NOTE : This selection chart is given for guidance only Actual cable dimensions must be considered before making final selections as these may vary due to manufacturing tolerances provided in BS 6346 : 1989

CABLE GLAND SECTION GUIDELINES

  CABLE TYPE
UNARMOURED SINGLE WIRE ARMOUR
CONDITION SEAL NO SEAL OUTER SEAL INNER & OUTER SEAL
Clear & Dry A2 BW CW E1W
External Moisture A2   CW E1W
Internal Moisture A2     E1W
Dust & Oil A2   CW E1W

Brass Cable GlandBW General purpose indoor application.
Brass Cable GlandA2, CW, E1W indoor and outdoor application.

ENTRY THREAD :
Normally glands have metric entry thread forms.
Metric threads 1.5 mm pitch are standard upto 75 mm.
Other thread forms like IMPERIAL, PG, NPT are also available on request.

 

 

Any kind of cable glands, brass cable glands, brass industrial cable glands can be developed and supplied exactly as per customers drawings and specifications.



 